The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:
Payments processed by PayPal or Takepayments are 100% secure.
Delivery via Royal Mail or APC Courier
We will accept goods for return up to 14 days from our shipment date. See our returns page
The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:
The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating signalling cell over voltage or cell over temperature.
In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3 seconds. After 2 attempts to reengage with 3 seconds delay the delay increases to 10 minutes. Whenever battery voltage is less than 13.5 V (resp. 27 V or 54 V) the Cyrix will disengage with a delay of 1 hour.
Note: In case of zero discharge current or a small discharge current the Cyrix will not disengage shortly after the charger has been switched off and/or disconnected because battery voltage will remain higher than 13.5 V. If after the Cyrix has disengaged the output of the battery charger immediately increases to 13.7 V or more the Cyrix will reengage with 3 seconds delay.
Download PDF